| The DLA-12 Reverse Osmosis Drain Line Adapter can be used anywhere a drain saddle is typically installed undercounter, providing a code-listed solid professional connection. | |
| The DLA-12 will not be accidentally rotated or bumped out of alignment when moving supplies or replacing a waste basket under the sink. |
|
|
| LIST OF PARTS ENCLOSED | ||
| 1 | Drain Line Adapter with Quick Connect Push-In Connector or 1/2" Barb (DLA-9/12) | |
| 1 | 3-Way Repair Tee | |
| 3 | Slip Joint (SJ) Wing Nuts | |
| 3 | Slip Joint (SJ) Beveled Washers | |
| INSTALLATION PROCEDURES (Average time to install is typically 1-3 minutes) Vertical Installation |
|
| Step One: Cut 1-1/2" from center of tailpiece |
|
| Step Two: Loosen waste ell and mount repair tee |
|
| Step Three: Install DLA-9/12 adapter and insert RO drain tube |
|
| Horizontal Installation |
|
| Step One: Cut 1-1/2" from center of waste ell |
|
| Step Two: Mount repair tee, DLA-9/12 and insert drain tube |
|
| ||||||||||||||||